Systems to be Commissioned
(1) Building Envelope
- Insulation
- Glazing
- Vapor barriers
- All elements of the building exterior wall
- Roof
- Building pressure testing
(2) Life Safety
- Fire-resistive ratings
- Smoke barriers
- Smoke-tight partitions
- Stair pressurization system
- Fire command center
(3) HVAC Systems
- Air terminals
- Induction units
- Fan coil units
- Unit heaters
- Air handling units
- Energy recovery units
- Exhaust system
- Chilled water system
- Heating water system
- Steam system
- Humidifiers
- Fire and Smoke dampers
- Special applications
- Operating rooms (anesthetizing locations)
- Airborne infection isolation (AII rooms)
- Protective environment (PE)
- Data center
- Pharmacy
- Imaging
(4) Controls
- Workstations
- Systems graphics and dashboards
- Networks
- Controllers
- Sensors
- Actuators
- Meters
(5) Plumbing Systems
- Domestic cold water
- Meter
- Backflow preventers
- Booster pump
- Water softener
- Domestic hot water
- Water hater
- Recirculation system
- Sump pumps
- Natural gas
- Fuel oil
- Propane or synthetic natural gas
- Disinfection systems
- Rainwater harvesting
- Process cooling
(6) Medical Gas Systems
- Oxygen
- Bulk oxygen system
- Remote oxygen supply connection
- Nitrogen
- Nitrous oxide
- Medical vacuum
- Waste anesthesia gas disposal
- Instrument air
- Medical air
- Manifold rooms
- Master and area alarms
- Valves
- Source
- Future
- Riser
- Service
- Zone
(7) Electrical Systems
- Meter
- Primary transformers
- Main switchgear
- Panelboards
- Isolated power systems
- Power conditioners
- Power factor correction equipment
- Uninterruptible power supplies
- Step-down transformers
- Generators
- Paralleling switchgear
- Automatic transfer switches
- Lightning protection systems
- Grounding systems
(8) Fire Alarm Systems
- Work Stations
- Controllers
- Sensing devices
- Interface with life safety systems
- Interface with fire protection system
- Interface with HVAC system
- Interface with elevators
(9) Information technology
- Telephone
- Data
- Intercom
- Paging
- Doctor’s dictation
- Telemetry
- Security
- Master clock
- Dedicated antenna
- Television
- Nurse call
- Infant abduction
- Wireless access points
- Cellular phone repeaters
(10) Fire Protection System
- Backflow preventer
- Fire pump/jockey pump
- Drains
- Tamper and flow switches
- Valves
- Fire department connections
- Standpipes
- Sprinkler heads
- Pre-action systems
- Clean agent systems
(11) Interior Lighting
- Occupancy sensors
- Controls
(12) Exterior Lighting
- Controls
- Illumination levels
(13) Refrigeration
- Food services refrigerators
- Food services freezers
- Clinical refrigerators and freezers
- Blood banks
(14) Vertical Transport
- Elevators
- Escalators
- Dumbwaiters
(15) Materials Handling
- Pneumatic tube
- Linen and trash conveyance
- Electronic transportation vehicles (ETV’s)